본문 바로가기 주메뉴 바로가기

HOME  >  제조사별  >   

ENV432 (LISN)

주요 스펙

주파수 범위
  • :9 kHz to 30 MHz
Power Capacity
  • :Up to 32 A
Simulated impedance
  • :50 ohm with CISPR 16-1-2
RF disturbance power
  • :10 dB
Brief Description

The ENV432 four-line V-network meets the requirements of CISPR 16?1?2, EN 55016-1-2 and ANSI C63.4 for V-networks with a simulated impedance of (50 μH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz. The ENV432 comes with a Schuko socket (EUT 1) and a CEE 32 A socket (EUT 2) for connecting the equipment under test (EUT).
 

구매, 기술, 렌탈 문의  이성종 과장 / 010-4812-3482 / sjlee3482@gmail.com



Key Facts

  - Frequency range from 9 kHz to 30 MHz
  - Power-handling capacity up to 32 A, constant current
  - Simulated impedance (50 μH + 5 Ω) || 50 Ω in line with CISPR 16-1-2
  - V-network in line with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461D, E and F
  - Calibrated in line with CISPR 16-1-2 and ANSI C63.4


Features & Benefits
Air-core design and artificial hand
- The ENV432 four-line V-network is based on air-core inductances and contains an artificial hand.Built-in 10 dB attenuator pad
To ensure standard impedance irrespective of the measuring receiver's input attenuation, the ENV432 is equipped with a 10 dB attenuator pad.
Built-in pulse limiter (can be switched off)
- A built-in pulse limiter that can be switched off protects the measuring receiver's input.
Automatic temperature monitoring
- When the temperature inside the housing reaches about +50 °C, the fans of the ENV432 automatically switch on. This protects the V-network in case of a high constant current load.
Remote control with TTL levels (compatible with Rohde & Schwarz measuring receivers)
- TTL control inputs that can be driven by controllers or Rohde & Schwarz measuring receivers are provided for remote control of phase selection in an automatic test system.

구매, 기술, 렌탈 문의  이성종 과장 / 010-4812-3482 / sjlee3482@gmail.com

ENV432 사양 (Specifications)

Specifications
Frequency range   9 kHz to 30 MHz
Simulated impedance   50 μH + 5 Ω) || 50 Ω
Error limits in line with CISPR 16-1-2 magnitude and phase ±20 % and ±11.5°
Decoupling attenuation between power supply and measuring receiver port in line with CISPR 16-1-2 9 kHz to 50 kHz > 0 dB to > 40 dB (increases linearly with logarithm of frequency)
  50 kHz to 30 MHz > 40 dB
Test path to EUT
Maximum permissible constant current EUT 1 16 A
Mains voltage EUT 1 0 V to 240 V AC + 10 %
DC voltage EUT 1 0 V to 350 V DC + 10 %
Maximum permissible constant current EUT 2 32 A
Peak current (brief) EUT 2 50 A (2 minutes)
Mains voltage EUT 2 0 V to 240/415 V AC + 10 %
DC voltage EUT 2 0 V to 350 V DC + 10 %
Mains frequency   0 Hz to 60 Hz + 5 %
Test path to measuring receiver
Maximum permissible RF disturbance power from EUT   5 W
Voltage division factor between EUT and measuring receiver port built-in attenuator pad, calibration data supplied with V-network 10 dB ? 0.5 dB/+ 2.0 dB
Response threshold of built-in pulse limiter can be switched off 140 dB (μV) (nom.)
Power supply for fans and control logic
Mains voltage 115 V setting 100 V to 120 V AC ± 10 %
  230 V setting 220 V to 240 V AC ± 10 %
Mains frequency   50 Hz to 60 Hz ± 5 %
Power consumption   100 VA (nom.)
Connectors
Mains and DC voltage output front panel, EUT 1 Schuko socket
Mains and DC voltage output front panel, EUT 2 CEE socket (6 h)
RF output front panel, TO TEST RECEIVER N female, 50 Ω
Artificial hand front panel 4 mm connector, female, with knurled clamp
Mains and DC voltage input rear panel, MAINS CEE built-in connector (6 h)
Mains voltage input (auxiliary voltage) rear panel, POWER FOR FAN AND REMOTE CONTROL low-temperature connector with mains filter
Remote control input rear panel, REMOTE CONTROL 25-contact, D-Sub, female
Protective earth front panel and rear panel M8 threaded bolt
RF reference ground on both sides ground bar with seven M6 threads
General data
Operating temperature range   +5 °C to +45 °C
Storage temperature range   ?40 °C to +70 °C
Dimensions, overall W × H × D 446 mm × 289 mm × 500 mm
Weight   24 kg
Electrical safety observe notes in manual in line with EN 61010-1
EMC   in line with IEC/EN 61326-1
Emission   class B, in line with residential environment requirements
Immunity   in line with industrial environment requirements
Recommended Extras

 - EZ-21       Control Cable, 3 m, ESU, ESCI, ESPI, ESIB and ESxS to ENVxxx

 - EZ-21       Control Cable, 10 m, ESU, ESCI, ESPI, ESIB and ESxS to ENVxxx

 - EZ-25       150 kHz Highpass Filter For conducted emission measurements in the presence of high longwave mains disturbance signals

구매, 기술, 렌탈 문의  이성종 과장 / 010-4812-3482 / sjlee3482@gmail.com